Product Description

📊

Overview & Basic Info

Model NO.KYUF-3000LPH
ApplicationIndustry
Capacity3000lph
Recovery Rate85%
Desalination Rate> 97%
UF MembraneUfc90al
PumpCnp
Control ValveAutomatic or Manual
MaterialFull SS304 or U-PVC & FRP
DisinfectionUV Sterilizer / Ozone
Voltage110V / 220V / 380V
Frequency50 Hz / 60 Hz
Power1.5 Kw
Warranty1 Year
CertificateCE & ISO & SGS
Production30 Sets /Month
💧

Product Description

Ultrafiltration (UF) technology is a pressure-driven membrane separation process that removes suspended or particular matters (including colloids & silt) from water. It serves as a superior pretreatment for surface water, sea water, and biologically-treated municipal effluent before reverse osmosis and other membrane systems. This solution is significantly more reliable than conventional multimedia filters. In addition to superior turbidity removal, UF membranes efficiently remove bacteria and most viruses.

UF Water Purifier System

Technical Parameters (3TPH System)

Component Material Functionality
Raw Water PumpSUS-304Provides pressure for pre-treatment filters
Sand FilterFRPRemoves sediment, manganese, rust (>20UM)
Activated CarbonFRPRemoves odor, organics, and pesticide pollution
Water SoftenerFRPRemoves Calcium (Ca2+) and Magnesium (Mg2+)
Security FilterSUS-304Removes fine particles and small colloids
UF MembraneUFc90ALRemoves impurities greater than 0.001 micron
UV Sterilizer40WKills bacteria for direct drinking water safety
🔍

Detailed Photos & Working Process

Detail 1
Process Chart
STEP 1: Sand Filter

Uses sand media (0.5-1mm) to trap suspended solids like colloids, rust, and mud down to 200 microns.

STEP 2: Carbon Filter

Absorbs organic matter, dissolved air, odor, and color from the water source.

STEP 3: Softener

Utilizes cation exchange resin to remove hardness (Calcium/Magnesium).

STEP 4: Micron Filter

Uses 5-20 micron sediment cartridge filters to ensure safety before the UF entrance.

STEP 5: Ultra-filtration System

The UF membrane traps most ions to de-mineralize and desalt, producing PURE WATER.

System Assembly
🌟

Advantages & Application

System Advantages

  • Advanced and famous ultrafiltration membrane elements for high reliability.
  • High recovery rate with no phase transformation during the process.
  • Low energy consumption and short production cycles.
  • Compact footprint, simple operation, and low labor intensity.
  • Automatic backwash to reduce pollution and prolong membrane life.
  • Continuous water production with high automation levels.

Application Fields

  • Pure and ultrapure water equipment for industrial use.
  • Sterile raw water equipment for pharmaceutical industry.
  • Purification for beverages, drinking water, and mineral water.
  • Wastewater treatment: electroplating, electrophoretic coating, and oily wastewater.
🔧

Maintenance Guidelines

Spare Part Advised Replacement Time Quantity
Quartz SandEvery 15-18 months200kg
Activated CarbonEvery 15-18 months75kg
PP CartridgeEvery month5 pcs
UF MembraneEvery 1-2 years6 pcs
UV LightEvery 1 year1 pc

*Replacement periods depend on the specific feed water quality.

🏢

Exhibition & Certifications

Factory View
Workshop
Inventory
Exhibition
Certifications
Quality Assurance
📝

Guidelines for Getting Quote

  • Specify the source water type (tap water, underground water, etc.).
  • Provide a water analysis report if available.
  • Define required production capacity (e.g., 500 LPH, 3000 LPH).
  • State the intended use (drinking, bottling, or industrial).

Frequently Asked Questions

What is the main difference between UF and RO systems?
UF (Ultrafiltration) removes suspended solids, bacteria, and viruses while retaining minerals. RO (Reverse Osmosis) removes almost all dissolved solids and minerals, providing a higher level of purification.
How much water can this system recover?
This UF system features a high recovery rate of approximately 85%, making it highly efficient for industrial and commercial use.
Does the system require professional installation?
The system is designed for ease of use. While professional setup is recommended for industrial configurations, it features automated switches and intuitive controls for daily operation.
What kind of maintenance does the UF membrane need?
The membrane should be replaced every 1-2 years depending on the raw water quality. The system includes an automatic backwash function to reduce pollution and extend the membrane's life.
Can this system handle different voltages?
Yes, the system is compatible with 110V, 220V, and 380V power supplies at both 50Hz and 60Hz frequencies to suit international standards.
Is the water produced by this system safe for direct drinking?
Yes, especially when equipped with the UV sterilizer or Ozone generator, the system effectively kills bacteria and viruses, making the output suitable for direct consumption.

Related Products